Reading thermal deltas: when +12 °C means a work order

Every thermal survey finds warm pixels. The craft is deciding which of them are faults. These are the rules our solar module applies before a hotspot is allowed to become a work order.

Delta-T, not absolute temperature

A panel reading 54 °C means nothing by itself; on a July afternoon the whole array might be there. What matters is the difference between a cell and its neighbors under the same irradiance, the ΔT. Our default alert threshold is +12 °C over the local median, which aligns with the IEC 62446-3 guidance for cell-level anomalies under stable conditions. Below that, we log and trend; above it, we open a finding.

Ambient compensation, or why noon flights lie less

Thermal contrast scales with irradiance. The same cracked cell that shows +18 °C at 850 W/m² can show +6 °C under thin cloud and disappear entirely at dawn. Examin reads the irradiance context from flight metadata and timestamps, and normalizes findings so that a survey flown at 09:30 in March is comparable with one flown at 13:00 in July. Two practical rules for pilots: fly above 600 W/m², and avoid the hour after rain, when evaporative cooling flattens every delta.

The false positives we suppress

  • Sky and structure reflections. Glass reflects the sky's apparent temperature. Reflection artifacts move between frames while faults stay put, so multi-frame tracking removes them.
  • Soiling shadows. Bird fouling reads hot, but with a signature (sharp edge, surface position) that classifiers separate from cell damage. The fix is a cleaning crew, not an electrician, and the work order says so.
  • Junction boxes. Every panel has a warm junction box. A model that does not know panel geometry files thousands of them as faults; ours masks them by design.

Severity is capacity at risk, not just degrees

A +14 °C single cell on one panel is a note. A +9 °C signature across a whole string is lost yield right now, because string-level heating usually means a connection or bypass-diode fault affecting every panel on the circuit. Examin ranks findings by estimated capacity affected × ΔT × growth since the last flight, which is why a "cooler" string fault outranks a "hotter" single cell in the queue.

From finding to work order

Each confirmed finding exports with the panel's row and position, GPS coordinates, the radiometric frame, the classification (cell fault, string fault, soiling, shading, junction anomaly), and the ranking. Crews sort by severity and geography and clear the list in one pass. On a recent 1.4 MW rooftop portfolio, this pipeline turned a three-day quarterly walk-down into one flight morning with findings the same day; the full numbers are in the case study.

What to trend, not just fix

Keep every survey. Cell faults that grow 2 to 3 °C per season are degrading and worth warranty claims while coverage lasts; stable ones can wait for scheduled maintenance. The trend line is the difference between evidence and anecdote when the module manufacturer pushes back, and manufacturers do push back.